ITG

主页产品类别EMI filterF2779Y001L-003

EMI filter

F2779Y001L-003 系列

Filter

MRI Room data line filters provide clean communication to equipment used inside MRI rooms to prevent interference with scanning equipment.

*** For new design or construction project, please select F2779Y002L-011 ***

  • MRI Room data line filters provide clean communication lines into MRI rooms. The filters are designed with minimum leakage current to ground and provide 100dB attenuation from 1MHz to 10GHz, Pass Band 0-200KHz.
  • Voltage Rating: 120/250V
  • Frequency: DC to 60Hz
  • Hi-Pot: Line to Ground: 1000VDC for 2 sec Line to Line: VDC for 2 sec
  • Ambient Temperature Range: -25°C To +85°C
  • Filter components are encapsulated in a plated metal enclosure
  • Leakage Current: 5mA @ 120VAC 60Hz
  • Comply with UL and cUL construction requirements

F2779Y001L-003 系列的电气特性